Gas and diesel generators

Generators sized for how you will run them: as backup during load-shedding, as your main supply, or around the clock. We have supplied, installed and serviced generators in Pakistan for over twenty years, as an authorized Generac distributor.

Generator range: Generac industrial canopy and containerized sets, an open industrial set, a home standby unit, a portable generator and a Tricom set
  • Hands-free changeover

    An automatic transfer switch starts the set and takes the load the moment the grid fails.

  • Sized to your load

    A load study at your site, so you do not pay for capacity you will never use, or run short.

  • Service around the clock

    Our own service team, 24 hours a day, 365 days a year, with every job tracked.

  • Parts in 96 hours

    Genuine spare parts within 96 hours, with doorstep delivery available.

Standby, prime or continuous

The same engine is rated differently depending on how it will be used. We size every set from a load study, so it is rated for the duty it will actually see.

Standby

Runs only when the grid fails. Load varies, and running hours per year are limited. Suits homes, offices, hospitals and shops on a mostly reliable supply.

Prime

The main source of power, with unlimited running hours at a varying load. Suits factories, sites with long outages and places off the grid.

Continuous

Runs non-stop at a steady base load, for unlimited hours. Suits process industry and captive power plants.

Gas or diesel

Gas generators run on pipeline natural gas, with no fuel to store or deliver and lower running costs where a gas connection is available. Diesel generators carry their own fuel, so they work anywhere and pick up load quickly.

We recommend the fuel based on your site, your gas connection and how many hours a year the set will run.

  • Generac generators, as an authorized distributor for over 20 years
  • Tricom diesel generating sets on Cummins, Perkins and Yangdong engines
  • Automatic transfer switches for hands-free changeover on grid failure
  • Weather and soundproof canopies
  • Sized from a load study, not a guess

From our sites

Sets we have built, delivered and installed, from compact canopies to containerized plants lifted into place at night.

Tricom diesel generating sets

For factories, commercial buildings and larger loads, we build diesel gensets on proven engines and specify every component to the job.

EnginesCummins, Perkins (UK), Yangdong
AlternatorsStamford or Leroy Somer on Cummins and Perkins sets, sized to the kW rating. Brushless alternators on Yangdong sets.
ControllersDeepSea 4520 or 4620 up to 200 kVA prime. DeepSea 6020 or 6120 above 200 kVA prime.
FuelBase fuel tank for roughly 8 to 10 hours at full load
EnclosureOpen type as standard. Weather and soundproof canopy available.
WarrantyCummins and Perkins: 12 months or 2,000 hours, whichever comes first. Yangdong: 12 months or 1,000 hours.

Service that keeps it ready

A generator is only useful if it starts. Our service teams keep standby, prime and continuous-duty sets in working order, and our CARE ERP system tracks every job from complaint to invoice.

24/7
Service, 365 days a year
96 hrs
Genuine parts supplied within 96 hours
  • Supply, installation, testing and commissioning
  • Service contracts with scheduled maintenance logs
  • Overhauling of diesel and gas generators to manufacturer standards
  • Alternator repair and rewinding
  • Cylinder head, turbocharger and oil pump rebuilding
  • Design and manufacture of AMF, ATS and synchronization panels
  • Genuine spare parts, with optional doorstep delivery

What affects the price

Two generators with the same kVA rating can be priced very differently. These are the choices that move the number. Your written proposal lists exactly what is included.

Get a priced proposal
Size
The kVA rating your load study calls for.
Fuel
Gas or diesel, and whether a gas connection is available.
Engine and brand
Generac, or Tricom sets on Cummins, Perkins or Yangdong engines.
Enclosure
Open set, weather and soundproof canopy, or container.
Controls
ATS, AMF or synchronization panels for running sets together.
Installation
Cable runs, foundation, exhaust, and lifting or crane work.

Generator questions

Ask us something else
What size generator do I need?

It depends on what has to stay on during an outage and how long the set will run. We size every generator from a load study at your site, so you do not pay for capacity you will not use.

Should I choose gas or diesel?

Gas generators run on pipeline gas, so there is no fuel to store and running costs are usually lower where a gas connection is available. Diesel works anywhere and picks up load quickly. We recommend one after looking at your site and running hours.

Can the generator switch on automatically when the power goes?

Yes. We install automatic transfer switches (ATS) so the generator starts and takes the load on its own when the grid fails, and hands back when it returns.

What warranty do I get?

Tricom sets on Cummins and Perkins engines carry 12 months or 2,000 running hours, whichever comes first. Yangdong sets carry 12 months or 1,000 hours. Generac generators carry the manufacturer’s warranty.

How fast can you get spare parts?

We supply genuine spare parts within 96 hours, with doorstep delivery available. Our service team is available 24/7, 365 days a year.

Find the right generator for your load

Tell us what has to stay on during an outage. We'll size it and send a written proposal.